Send Message
  • English
Home ProductsDigital Humidity Controller

SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE

Certification
China Shenzhen Creatall Electronics Co., Ltd. certification
China Shenzhen Creatall Electronics Co., Ltd. certification
Customer Reviews
Great products from a good supplier, goods are working nicely ⭐⭐⭐⭐⭐I will order again thank you!

—— Gift Adonsi

I received my parcel well on time everything was done above board the salesman was very helpful. The quality of the product is very good. I do not hesitate to do business with them again.

—— Anyway Violah

perfect timing n communication perfect on product information perfect on after sales support perfect on shipping time

—— Ismail Khamis

So good quality module is provided by the seller. And easy to communicate very fast responding also.

—— Sayanik Mandal

What a good service from creatAll, very responsible! Good Job! Nice to have a business with u

—— Erick Setiawan

I'm Online Chat Now

SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE

SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE
SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE

Large Image :  SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE

Product Details:
Place of Origin: China
Brand Name: Original
Certification: CE
Model Number: SHT2000
Payment & Shipping Terms:
Minimum Order Quantity: 10pcs
Price: negotiable
Delivery Time: 5-8 work days

SHT2000 Digital Humidity Controller LED Hygrometer Power Switch CE

Description
Humidity Range:: 00%~99%RH Humidity Control Accuracy:: 0.1% RH
Measurement Accuracy:: +/- 2% RH Load Power:: 12v 120w Or 24v 240w Or 220v 1500w (depending On Your Choice)
MAX Output:: 10A Output Type:: Direct Output
Highlight:

SHT2000 Digital Humidity Controller

,

Digital Humidity Controller CE

,

LED Hygrometer Power Switch

Digital Temperature Humidity Controller SHT2000 LED Thermoregulator Thermostat Humidistat Hygrometer Switch

Description:

Setting method: Start value Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)
Heating/cooling mode setting
Setting mode: setting (starting temperature): Press and hold the button to start the temperature flashing. Use key to set the starting temperature value.
Setting (stop temperature): Press and hold the button to stop the temperature flashing. Use to set the stop temperature value.

Heating use case:
control the water heater, heat to 65 ° C to stop, the temperature drops back to 50 ° C and start heating again
The first step: heating mode, starting temperature
Step 2: Press and hold the button to start the temperature flashing. Use to set the starting temperature to 50 °C.
Step 3: Press and hold the button to stop the temperature flashing. Set the stop temperature to 65 °C with keys, and the setting is completed!

Refrigeration use case: use in the farm, the fan is ventilated to 26 ° C to stop, the temperature is raised to 30 ° C and the ventilation is started again.
The first step: cooling mode, starting temperature > stop temperature
Step 2: Press and hold the button to start the temperature flashing. Use to set the starting temperature to 30 °C.
The third step: long press the button to stop the temperature flashing, set the stop temperature to 26 °C by , the setting is completed!

Humidification/Dehumidification Mode Settings:
Setting (start humidity): Press and hold key to start the humidity value flashing. Set the humidity value by key. Set [Stop Humidity]: Press and hold key to stop the humidity value flashing, and set the humidity to stop by key value.

Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification.
 
Setup steps:
Step 1:
Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH.
Step 2: Press and hold the button for 3 seconds to stop the humidity value flashing. Set the value to 80% RH. After the setting is completed, the button will be operated for 5 seconds without returning to the normal display state.

Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification

Setup steps:
Step 1:
Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40%RH.
Step 2: Press and hold the button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.

Contact Details
Shenzhen Creatall Electronics Co., Ltd.

Contact Person: alvacheng

Tel: +86-136827494627

Fax: 86-755-85270755

Send your inquiry directly to us (0 / 3000)